Tetra Four Gas Monitors are simple to use,
reliable, rugged and fully weather protected. Designed using the latest
technologies, Tetra uses a single button
operation and intelligent sensor modules to guarantee simplicity and
flexibility of use. The shockproof internal construction and self checking
software assure reliable gas detection in the most arduous of environments.
Tetra is a unique multigas monitor for the detection of flammable gases,
oxygen and toxic gases. Tetra offers flexibility, assurance, ruggedness and
real value for money. Intrinsically safe, Tetra is the only portable gas
detector with embedded software designed to the exacting requirements of IEC
61508-3 guaranteeing reliable and dependable operation. Tetra is a four
channel multi gas monitor with an integral vibrating alarm. Pumped Tetra is
supplied with a charger, aspirator plate, 3yd Neoprene hose & in-line
filter. Non-pumped
Tetra is also supplied with an Aspirator bulb.

 |
- Up to four gases measured
- Digital interchangeable i-module sensors for full flexibility
- Loud 90dBA audible alarm with selectable tones
- Unique dual color red/blue visual alarm
- Built in vibrating alarm as standard
- Rugged and robust, IP65 ingress protection
- Simultaneous 4 gas display with automatic backlight
- Peak mode operation
- TWA reading recall
- Data & Event logging
- Simple IR interface to PC
|
|
Tetra is especially easy to use. A single button
provides all the control functions such as switch on, switch off, alarm
reset, and access to a small functional menu which provides for peak and TWA (8 hour) This one button operation process has been market tested in
Custodian CDL and has been proven to be popular. Tetra gives an audible
confidence beep every 10 seconds, and flashes ‘OK’ in normal operation on
the screen at the same time. In the event of a change of status from ‘OK’
a warning symbol replaces the OK. The display provides pop up screen
warning messages for operational status other than normal.
Tetra is designed to have the most effective alarms on
the market place featuring the following:
A unique
blue/red flashing LED visual alarm. Blue flashing LEDS are far brighter
than any other color, and we have chosen a blue/red combination, as some
standards require a red indicator for gas concentration alarms.
The alarm
sounder has a high output and a range of selectable tones, which allow
allocation of preferred or differing tones to the different alarm levels.
Tetra features a built in
vibrating alarm as standard.

Tetra features full simultaneous display, showing gas
concentration with gas name and units for each channel in normal
operation. In alarm condition the main audible/visual and vibrating alarms
are activated and the display shows the highest current alarm level. The
alarm LEDs are on the top of the unit to be fully visible at all times.
The display gives comprehensive indication of gas concentrations and any
relevant alarm or status information, and is fully backlit. Battery status
is continuously displayed with a symbol showing up to six bars
representing remaining life and providing a low battery alarm.
|

Crowcon Tetra - 4 gas personal monitor
Tetra has an integral belt mounting clip and can be
used with a typical range of optional accessories for wearing and carrying
– a universal harness clip allows the use of a shoulder strap or chest
harness, and an optional carry case is available.
Tetra can be used for diffusion sampling, for active
sampling using a manual aspirator (TET/02), for active sampling using an optional
built in electric sampling pump (TET/01). For both pumped sampling and aspirator
sampling a simple clip on plate is used with either just a sampling line
or an aspirator kit as appropriate. Standard Crowcon sampling accessories
such as probes, water traps etc are suitable for use with this product.
Pumped units give a clear indication of pump operation on the display as
well as indication of flow fail in case of pump stall or blockage.
Tetra is available as either a rechargeable unit
utilizing a lithium-ion battery or a non-rechargeable version utilizing
3-AA alkaline batteries. The non-rechargeable version has a slightly
taller outer case to accommodate the batteries. The rechargeable version
has a built in charger circuit requiring an external power supply. This is
a custom supply with some additional built in protection components
necessary to ensure the integrity of the safety components within the
product. The supplies are available either as a wall socket plug for UK,
European and USA type outlets or as an in line supply with flying leads
for places where these are not used. Operating life for the rechargeable
units on a full charge is more than 12 hours and for alkaline batteries
more than 18 hours.
Tetra features Event Logging, i.e. rather than just
filling up a data file with minute-by-minute data records, data is written
to memory when something significant happens e.g. an alarm threshold is
crossed. This means where an instrument needs to be interrogated following
an incident the relevant data is quickly and immediately available, and is
not obscured by large quantities of meaningless timed data. |

|
Description |
Catalog No.
|
Price |
|
| Tetra with LEL, Oxygen, Carbon Monoxide
& Hydrogen Sulfide Sensors & Built in Pump |
TET-01/ABCD |
$970.00 |
 |
| Tetra with LEL, Oxygen, Carbon Monoxide & Hydrogen Sulfide
Sensors |
TET-02/ABCD |
$860.00 |
 |
| Confined Space Kit
The kit contains chest harness, shoulder strap, communications software,
aspirator plate w/Tee Connector. 34Litre mixed test gas cylinder (LEL/OX/CO/H2S),
regulator, pc interface and carrying (brief) case with foam inserts and
Crowmag. Use with Tetra Software Version 1.v09 and up ** PC Interface is 9
pin serial** USB adapter available in Tetra parts list |
CSK-03
|
$590.00 |
 |
|
Confined Space Kit The kit contains
chest harness, shoulder strap, communications software pc interface and
carrying (brief) case with foam inserts and Crowmag. ** PC Interface is 9
pin serial** USB adapter available in Tetra parts list. |
CSK-02
|
$340.00 |
 |
| 3' Sample Probe |
C01097
|
$107.00 |
 |
| Telescopic Aspirator Probe |
C01757
|
$121.00 |
 |
| Water Trap |
C01245
|
$275.00 |
 |
| Wizard field calibration station-Wizard
field calibration station Supplied with 34 liter four gas mix cylinder,
regulator , case (Will hold Tetra), aspirator plate w/Tee Connector and
crow-mag. Use with Tetra Software Version 1.v09 and up |
WIZ-001 |
$480.00 |
 |
Click here to view all Tetra Accessories
Instrument Specifications
| Audible Alarms |
90 dBA at 1 foot, multiple alarm sounds
allow selection of distinctive tones for different alarm levels |
The following modules are available for inclusion in any Tetra monitor and
can be substituted in lieu of the gases shown as standard above: |
| Visual Alarms |
Dual color red/blue flashing LED pair in gas hazard |
GAS
Flammable
Oxygen
Hydrogen Sulphide
Carbon Monoxide
Sulphur Dioxide
Chlorine
Nitrogen Dioxide
Ammonia
Ozone
Hydrogen
N/A N/A
Hydrogen Cyanide
Hydrogen Fluoride
Phosphine
|
RANGE
0-100%LEL
0-25%
0-50ppm
0-500ppm
0-10ppm
0.5ppm
0-10ppm
0-50ppm
0.1 ppm
0-1000ppm
0-25ppm
0-10ppm
0-2ppm
|
Alarm
UK/ROW20%LEL
19/23.5%
5ppm
30ppm
2ppm
0.5ppm
3ppm
25ppm
0.1 ppm
N/A
5ppm
1ppm
0.2ppm
|
Alarm
USA10%LEL19.5/23.5%
10ppm
35ppm
2ppm
0.5ppm
3ppm
25 ppm
0.1 ppm
N/A
5 ppm
1 ppm
0.2 ppm
|
| Vibrating Alarm |
Internal |
| Display |
Graphic LCD with backlight, giving simultaneous display
for all gas channels. Graphic symbols for battery (with proportional
indication of remaining operation time), pump operation, healthy operation
or fault warning. Start up indication when calibration is due within 30
days, calibration overdue or service required. |
| Display Mode |
Normal display for continuous real time gas concentration levels,
display recall for Peak readings and TWA
|
| Datalogging |
Event logging, 8000 event capacity |
| Battery Type |
Rechargeable Li-Ion battery or non
rechargeable pack 3 x AA alkaline cells |
| Operating Time |
Rechargeable: 12 hours minimum |
| Alkaline: 11 hours minimum |
| Sampling |
Hand aspirator or internal electric
sampling pump |
| Temperature Range |
-4 to 131°F |
| Humidity |
0-99% RH |
| PC Interface |
IR link for RS232 connection. USB/RS232 converter
available. Portable PC software package provides full configuration
control, calibration and access to the Event Log file |
| Auto calibrator |
Tetra can be routinely calibrated using
the Crowcon Auto calibrator II in conjunction with the Portables PC
software |
| Approvals |
Class I, Div I, Groups A, B, C, D, ATEX II2G EEx iad IIC
T4 BASEEFA 03ATEX0193 |
| Ingress Protection |
IP 65 |
| Weight |
1.1 pounds |
| Dimensions |
Rechargeable: 4.75" x 5" x 2.5" |
| Alkaline: 5.25" x 5" x 2.5" |
Prices listed July 16, 2007
|