Fell 21 System

Home
All Products
Locators & Detecting Tools
Measuring Equip
Hand Tools
Power Tools
Safety
Water Works Products
WasteWater
Contact Us
POWER
Repair Service

 

 

The Fell-21 "Reads" and locates cracks and faults in non metallic Sewer/Drain or Vacuum lines.  The line under test is plugged temporarily with a common Rubber plug.  The line is then "surcharged" or filled with water.  The Sonde is mounted on to the end of a fiberglass push rod.  The Sonde is pushed down the line by hand until it reaches the Rubber Plug.  The Palm computer (PDA) is hard wired to the Sonde head and is in constant communication with it.  The Sonde is activated and begins to emit a small electrical charge that travels through the water that surrounds it.  The fiberglass push rod is now pulled back toward the operator.  As the Sonde travels through the pipe the electrical charge that it emits is constantly searching for a break or crack or some other type of defect in the line.  A break or crack lets the electrical charge escape temporarily to earth ground.  Whenever this occurs  the strength of the electrical loss is measured on the Palm Computer. This loss can be measured and plotted on the screen as to the size and length of the crack or defect.  The exact location of these cracks and defects are also plainly shown on the screen allowing the technician to pinpoint precisely where the line needs to be repaired. This information can be uploaded to another computer and/or it can be printed out on the spot for verification and analysis and shown to the customer.

The FELL 21 COMPLETE SYSTEM: Consists of 165' Fiberglass Push Rod with Sonde and counter assembly, 165' Air Line with 3" to 6" plug, Heavy duty Manual Air Pump with gauge, Dell Axim Color palm computer, HP Graphic printer for on site reports, 115 Volt and 12Volt Charger Adapters, Ground wire, Heavy Duty Pelican Water resistant and lockable carry case.

 

 

 

 

 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation:
The service can be tested from the cleanout in the cellar or from the cleanout outside of the building:
Push plug to end of lateral, inflate and surcharge lateral.
Push FELL-21 sonde to plug.
Pull sonde through lateral at about 30ft/min – sonde current is displayed in real time .

If the clean out allows adequate work space,  the upstream side of the service can be done as follows:
Relocate plug to just downstream of clean out.
Push sonde to upstream end of lateral.
Pull sonde through lateral at about 30ft/min
Leak results are seen immediately on the screen of a Dell
  hand held computer (included in FELL 21 package)

To visit the Fell Home page please click here:  http://www.fell21.com/FELL21.html

   

 

Qty      

P/N

Description

1

FELL2B

I/O Controller, Pocket PC and Enclosure, Connecting Cables, Accessories Box, Battery Charger, Software and User Manual

1

FELLS20

S20 Sonde, push rod and reel (200ft)

1

FELLBT

Bluetooth communications for PC

1

EEB

Earth/ground stake

1

7HK25B

Cable reel with 82 ft cable for ground stake

 

 

 

C.A.Turner Co.,Inc.  6 Marshall St.  Leicester, MA  01524     Tel 800-228-4032   Fax 508-752-5750